XT-331 Unarmoured Fire Resistant Instrumentation Cable Collective Screen to IEC 60092-357
XT-331 Fire Resistant Instrumentation cables were originally designed as a lightweight ship wiring cable. They have become popular throughout the petrochemical and process control industries due to their low smoke, low gas generation and increased flame retardant properties.
Manufacturers alternative reference: Helkama RFA-FRHF.
Construction:XTC: Copper or tinned copper conductors, Silicone insulation (or mica glass tape + XLPE insulation), aluminium/polyester foil screen and drain wire, SHF1 Low Smoke Halogen Free sheath – Orange.
This cable is also available in triples on request.
Image representative of product style, product supplied may vary.
Voltage Rating: | 150/250V (300V) |
Conductor Stranding: | IEC 60228 Class 5, plain copper or tinned copper |
Temperature Rating: | -15°C to +90°C |
Bending Radius Static: | 6 x overall diameter |
Flame Retardant: | IEC 60332-1-2, IEC 60332-3-22 |
Smoke Emission: | IEC 61034 |
Halogen Emission: | IEC 60754-1 & 2 |
Manufactured To: | IEC 60092 series |
3rd Party Approvals: | Lloyds, DNV, ABS, BV and Rina. |
Conductor Size: | 0.5mm² | 0.75mm² | 1mm² | 1.5mm² | 2.5mm² |
Conductor Resistance: | <36.0 Ohms/km | <26.7 Ohms/km | |||
Pair Capacitance @ 800Hz | |||||
Collective Screen: | 55nF/km | 50nF/km |
Order by 4.30pm for delivery by
Code | Description | mm² | Pairs | Colour | Sheath | Approval | Alternative to | Downloads | Pack Size | QTY | Price | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XTC0502PM |
2 x 2 x 0.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.5 | 2 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0504PM |
4 x 2 x 0.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.5 | 4 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0507PM |
7 x 2 x 0.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.5 | 7 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0510PM |
10 x 2 x 0.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.5 | 10 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0514PM |
14 x 2 x 0.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.5 | 14 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0519PM |
19 x 2 x 0.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.5 | 19 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0524PM |
24 x 2 x 0.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.5 | 24 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0530PM |
30 x 2 x 0.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.5 | 30 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0537PM |
37 x 2 x 0.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.5 | 37 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0702PM |
2 x 2 x 0.75mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.75 | 2 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0704PM |
4 x 2 x 0.75mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.75 | 4 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0707PM |
7 x 2 x 0.75mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.75 | 7 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0710PM |
10 x 2 x 0.75mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.75 | 10 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0714PM |
14 x 2 x 0.75mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.75 | 14 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0719PM |
19 x 2 x 0.75mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.75 | 19 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0724PM |
24 x 2 x 0.75mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.75 | 24 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0730PM |
30 x 2 x 0.75mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.75 | 30 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC0737PM |
37 x 2 x 0.75mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
0.75 | 37 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1002PM |
2 x 2 x 1.0mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1 | 2 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1004PM |
4 x 2 x 1.0mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1 | 4 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1007PM |
7 x 2 x 1.0mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1 | 7 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1010PM |
10 x 2 x 1.0mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1 | 10 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1014PM |
14 x 2 x 1.0mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1 | 14 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1019PM |
19 x 2 x 1.0mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1 | 19 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1024PM |
24 x 2 x 1.0mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1 | 24 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1030PM |
30 x 2 x 1.0mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1 | 30 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1037PM |
37 x 2 x 1.0mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1 | 37 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1502PM |
2 x 2 x 1.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1.5 | 2 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1504PM |
4 x 2 x 1.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1.5 | 4 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1507PM |
7 x 2 x 1.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1.5 | 7 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1510PM |
10 x 2 x 1.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1.5 | 10 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1514PM |
14 x 2 x 1.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1.5 | 14 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1519PM |
19 x 2 x 1.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1.5 | 19 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1524PM |
24 x 2 x 1.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1.5 | 24 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1530PM |
30 x 2 x 1.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1.5 | 30 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC1537PM |
37 x 2 x 1.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
1.5 | 37 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC2502PM |
2 x 2 x 2.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
2.5 | 2 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC2504PM |
4 x 2 x 2.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
2.5 | 4 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC2507PM |
7 x 2 x 2.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
2.5 | 7 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC2510PM |
10 x 2 x 2.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
2.5 | 10 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC2514PM |
14 x 2 x 2.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
2.5 | 14 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC2519PM |
19 x 2 x 2.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
2.5 | 19 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC2524PM |
24 x 2 x 2.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
2.5 | 24 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC2530PM |
30 x 2 x 2.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
2.5 | 30 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
|||||||||||||||||
XTC2537PM |
37 x 2 x 2.5mm² XT-331 Fire Resistant Instrumentation Cable to IEC 60092-376 Collectively Screened Pairs Orange LSHF
|
2.5 | 37 | Orange | LSHF | DNV-GL & ABS |
RFA-FRHF SH-CI-C-U-F S95 |
Datasheet | Get Quote | Get Quote | |||||||
|
Please contact us to request a quote for this item.
XT-331 Unarmoured Fire Resistant Instrumentation Cable Collective Screen to IEC 60092-357
Part No. G1555A sales representative will contact you within 3 hours, Monday to Friday 8am - 5pm.
Alternatively contact us on 01727 840 841
Request sent
Continue ShoppingPeople also viewed...
- XAT-331 Armoured Fire Resistant Instrumentation Cable Collective Screen to IEC 60092-357Code: G1554
- XAT Armoured Instrumentation Cable to IEC 60092-376Code: G1448
- XAT-331 Fire Resistant Armoured Instrumentation Cable to IEC 60092-376Code: G1451
- XAT-331 Fire Resistant Armoured Instrumentation Cable Individual Screen to IEC 60092-376Code: G1452
- XT-331 Unarmoured Fire Resistant Instrumentation Cable Individual Screen to IEC 60092-357Code: G1556